9.20.13.8. — Required Weep Holes

(1) Weep holes spaced not more than 800 mm apart shall be provided at the bottom of,

(a) cavities in cavity walls, and

(b) cavities or air spaces in masonry veneer walls.

(2) The cavities or air spaces described in Sentence (1) shall include those above lintels over window and door openings required to be flashed in conformance with Article 9.20.13.3.

(3) The weep holes required in Sentence (1) shall be in a location such that any water that collects in the cavity or space will be directed to the exterior of the building.