CodeChronicle

OBC 2006 Division B

9.15.4.4.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

New in this edition — no OBC 1997 predecessor

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.15.4.4. — Pro

9.15.4.4. — Foundation Walls Considered to be Laterally Supported at the Bottom

(1) Flat insulating concrete form foundation walls shall be considered to be laterally supported at the bottom where the foundation wall,

(a) supports backfill not more than 1.2 m in height,

(b) is supported at the footing by a shear key and is supported at the top by the ground floor framing, or

(c) is dowelled to the footing with not less than 15M bars spaced not more than 1.2 m o.c.

Text · e-Laws consolidated snapshot