CodeChronicle

OBC 2006 Division B

9.15.3.6.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · split from 9.15.3.3. — Pro

OBC 1997 · renumbered from 9.15.3.5. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.15.3.6. — Pro

9.15.3.6. — Adjustments to Footing Widths for Interior Walls

(1) The minimum strip footing widths for interior loadbearing masonry walls shown in Table 9.15.3.4.v1 shall be increased by 100 mm for each storey of masonry construction supported by the footing.

(2) Footings for interior non-loadbearing masonry walls shall be not less than 200 mm wide for walls up to 5.5 m high and the width shall be increased by 100 mm for each additional 2.7 m of height.

Text · e-Laws consolidated snapshot