CodeChronicle

OBC 2006 Division B

9.15.3.5.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · split from 9.15.3.3. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.15.3.5. — Pro

9.15.3.5. — Adjustments to Footing Widths for Exterior Walls

(1) The strip footing widths for exterior walls shown in Table 9.15.3.4.v1 shall be increased by,

(a) 65 mm for each storey of masonry veneer over wood frame construction supported by the foundation wall,

(b) 130 mm for each storey of masonry construction supported by the foundation wall, and

(c) 150 mm for each storey of flat insulating concrete form wall construction supported by the foundation wall.

Text · e-Laws consolidated snapshot