9.10.1.3. — Items Under Part 3 Jurisdiction

(1) Tents, air-supported structures, transformer vaults, walkways, elevators and escalators shall conform to Part 3.

(2) Where rooms or spaces are intended for an assembly occupancy, such rooms or spaces shall conform to Part 3.

(3) Basements containing more than 1 storey or exceeding 600 m2 in area shall conform to Part 3.

(4) Where rooms or spaces are intended for the storage, manufacture or use of hazardous or explosive material, such rooms or spaces shall conform to Part 3.

(5) Reserved.

(6) Openings through floors that are not protected by shafts or closures shall be protected in conformance with Subsection 3.2.8.

(7) Chutes and shafts shall conform to Subsection 3.6.3. except where they are contained entirely within a dwelling unit.

(8) Where sprinkler, standpipe and hose systems are installed, they shall be installed in conformance with Part 3.

Editor's note

As filed in O. Reg. 350/06, Sentence (5) of this article reads 'Reserved.' with a closing period. The consolidated e-Laws text renders it without the period ('Reserved'); the as-filed text is retained here.