9.10.1. — Definitions and Application

Content not available for this version.

9.10.1.1. — Support of Noncombustible Construction

(1) Where an assembly is required to be of noncombustible construction and to have a fire-resistance rating, it shall be supported by noncombustible construction.

Text · e-Laws consolidated snapshot

9.10.1.2. — Sloped Roofs

(1) For the purposes of this Section, roofs with slopes of 60° or more to the horizontal and that are adjacent to a room or space intended for occupancy shall be considered as a wall.

Text · e-Laws consolidated snapshot

9.10.1.3. — Items Under Part 3 Jurisdiction

(1) Tents, air-supported structures, transformer vaults, walkways, elevators and escalators shall conform to Part 3.

(2) Where rooms or spaces are intended for an assembly occupancy, such rooms or spaces shall conform to Part 3.

(3) Basements containing more than 1 storey or exceeding 600 m2 in area shall conform to Part 3.

(4) Where rooms or spaces are intended for the storage, manufacture or use of hazardous or explosive material, such rooms or spaces shall conform to Part 3.

(5) Reserved.

(6) Openings through floors that are not protected by shafts or closures shall be protected in conformance with Subsection 3.2.8.

(7) Chutes and shafts shall conform to Subsection 3.6.3. except where they are contained entirely within a dwelling unit.

(8) Where sprinkler, standpipe and hose systems are installed, they shall be installed in conformance with Part 3.

Editor's note

As filed in O. Reg. 350/06, Sentence (5) of this article reads 'Reserved.' with a closing period. The consolidated e-Laws text renders it without the period ('Reserved'); the as-filed text is retained here.

9.10.1.4. — Items Under Part 6 Jurisdiction

(1) In kitchens containing commercial cooking equipment used in processes producing grease-laden vapours, the equipment shall be designed and installed in conformance with Part 6

(2) Where fuel-fired appliances are installed on a roof, such appliances shall be installed in conformance with Part 6.

Editor's note

This map follows the as-filed text of O. Reg. 350/06 for Article 9.10.1.4. of Division B, in which Sentence (1) ('... shall be designed and installed in conformance with Part 6') ends without a sentence-ending period. The e-Laws consolidation editorially adds a terminal period, with no amending regulation making the change. This map preserves the as-filed wording.