OBC 2006 › Division B
9.1.1.9.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.1.1.9.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.1.1.9.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
Provenance
OBC 1997 · renumbered from 2.1.1.4. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 125 · ext v1 →
In force 2010-01-01
Next: O. Reg. 503/09, cl. 125 · ext (not in force until 2010-01-01) v1 →
OBC 2012 · continues as 9.1.1.9. — Pro
9.1.1.9. — Site Assembled and Factory-Built Buildings
Comparing versions
Changed text stands out · unchanged is dimmed
v0 base
Earlier · viewing · 2006-12-31(1) Except as provided in Sentence (2), a manufactured building intended for residential occupancy is deemed to comply with this Code if it is designed and constructed in compliance with,
(a) CAN/CSA-Z240.2.1, “Structural Requirements for Mobile Homes”, and CAN/CSA-Z240.3.1, “Plumbing Requirements for Mobile Homes”, if the building is constructed in Sections not wider than 4.88 m, or
(b) CAN/CSA-A277, “Procedure for Certification of Factory-Built Houses”.
(2) The requirements of this Code shall apply to,
(a) building components designed and constructed outside the place of manufacture, and
(b) site installation of such buildings.
v1 O. Reg. 503/09
Later · 2010-01-01(1) Except as provided in Sentence (2), a manufactured building intended for residential occupancy is deemed to comply with this Code if it is designed and constructed in compliance with,
(a) CAN/CSA-Z240.2.1, “Structural Requirements for Mobile Homes”, and CAN/CSA-Z240.3.1, “Plumbing Requirements for Mobile Homes”, if the building is constructed in Sections not wider than 4.88 m, or
(b) CSA A277, “Procedures for Factory Certification of Buildings”.
(2) The requirements of this Code shall apply to,
(a) building components designed and constructed outside the place of manufacture, and
(b) site installation of such buildings.
Provenance
OBC 1997 · renumbered from 2.1.1.4. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 125 · ext v1 →
In force 2010-01-01 comparing ×
Next: O. Reg. 503/09, cl. 125 · ext (not in force until 2010-01-01) v1 →
OBC 2012 · continues as 9.1.1.9. — Pro