(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.1.1.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 9.1.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.1.1. — Pro
9.1.1. — Application
Content not available for this version.
9.1.1.1. — Scope
(1) The scope of this Part shall be as described in Subsection 1.1.2. of Division A.
Text · e-Laws consolidated snapshot
9.1.1.2. — Signs
(1) Signs shall conform to the requirements in Section 3.15.
Text · e-Laws consolidated snapshot
9.1.1.3. — Self-Service Storage Buildings
(1) Self-service storage buildings shall conform to the requirements in Section 3.10.
Text · e-Laws consolidated snapshot
9.1.1.4. — Tents and Air-Supported Structures
(1) Tents shall conform to the requirements in Subsection 3.14.1.
(2) Air-supported structures shall conform to the requirements in Subsection 3.14.2.
Text · e-Laws consolidated snapshot
9.1.1.5. — Proximity to Existing Above Ground Electrical Conductors
(1) Where a building is constructed in close proximity to existing above ground electrical conductors the requirements of Subsection 3.1.19. shall apply.
Text · e-Laws consolidated snapshot
9.1.1.6. — Food Premises
(1) The requirements of Subsection 3.7.6. apply to all food premises.
Text · e-Laws consolidated snapshot
9.1.1.7. — Radon
(1) In addition to all other requirements, a building in the following designated areas shall be designed and constructed so that the annual average concentration of radon 222 does not exceed 250 millibecquerels per litre of air and the annual average concentration of the short lived daughters of radon 222 does not exceed 0.02 working levels inside the building for,
(a) the Town of Elliot Lake in the Territorial District of Algoma,
(b) the Township of Faraday in the County of Hastings, and
(c) the geographic Township of Hyman in the Territorial District of Sudbury.
Text · e-Laws consolidated snapshot
9.1.1.8. — Building in Flood Plains
(1) Buildings constructed on flood plains shall,
(a) be designed and constructed in accordance with good engineering practice to withstand anticipated vertical and horizontal hydrostatic pressures acting on the structure, and
(b) incorporate floodproofing measures that will preserve the integrity of exits and means of egress during times of flooding.
Text · e-Laws consolidated snapshot
9.1.1.9. — Site Assembled and Factory-Built Buildings
(1) Except as provided in Sentence (2), a manufactured building intended for residential occupancy is deemed to comply with this Code if it is designed and constructed in compliance with,
(a) CAN/CSA-Z240.2.1, “Structural Requirements for Mobile Homes”, and CAN/CSA-Z240.3.1, “Plumbing Requirements for Mobile Homes”, if the building is constructed in Sections not wider than 4.88 m, or
(b) CAN/CSA-A277, “Procedure for Certification of Factory-Built Houses”.
(2) The requirements of this Code shall apply to,
(a) building components designed and constructed outside the place of manufacture, and
(b) site installation of such buildings.
Text · e-Laws consolidated snapshot
9.1.1.10. — 9.1.1.10.
Not in force at this date.
9.1.1.11. — 9.1.1.11.
Not in force at this date.
Provenance
OBC 1997 · continues from 9.1.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.1.1. — Pro