8.4.1. — General Requirements

Content not available for this version.

8.4.1.1. — Scope

(1) This Section applies to the construction of a Class 2 sewage system.

Text · e-Laws consolidated snapshot

8.4.1.2. — Application

(1) A Class 2 sewage system shall be designed only for the treatment and disposal of greywater.

(2) The total daily design flow for a Class 2 sewage system shall be calculated based on the fixtures discharging to the system as follows:

(a) 200 L per fixture unit where there is a supply of pressurized water, and

(b) 125 L per fixture unit where there is no supply of pressurized water.