CodeChronicle

OBC 2006 Division B

8.3.2.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 8.3.2.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 8.3.2.1. — Pro

8.3.2.1. — Construction Requirements

(1) A privy as described in Subsections 8.3.3. to 8.3.5. shall be enclosed with a superstructure that,

(a) is constructed of strong durable weatherproof materials,

(b) has a solid floor supported by a sill constructed of treated timber, masonry or other material of at least equal strength and durability,

(c) is easily sanitized,

(d) unless it is equipped solely as a urinal, is equipped with one or more seats each having a cover and being supported by an enclosed bench or riser that is lined with an impervious material on all interior vertical surfaces,

(e) is equipped with a self-closing door,

(f) has one or more openings for purposes of ventilation, all of which are screened,

(g) has a ventilation duct that is screened at the top end and that extends from the underside of the bench or riser to a point above the roof of the superstructure, and

(h) shall not have any openings for the reception of human body waste, other than urinals and those constructed in accordance with Clause (1)(d).

Text · e-Laws consolidated snapshot