OBC 2006 › Division B
7.4.3.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.4.3.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.4.3.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 7.4.3. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 7.4.3. — Pro
7.4.3. — Location of Fixtures
Content not available for this version.
7.4.3.1. — Plumbing Fixtures
(1) Sanitary units, bathtubs and shower baths shall not be installed adjacent to wall and floor surfaces that are pervious to water.
Text · e-Laws consolidated snapshot
7.4.3.2. — Restricted Locations of Indirect Connections and Traps
(1) Indirect connections or any trap that may overflow shall not be located in a crawl space or any other unfrequented area.
Text · e-Laws consolidated snapshot
7.4.3.3. — Equipment Restrictions Upstream of Interceptors
(1) Except as provided in Sentence (2), equipment discharging waste with organic solids shall not be located upstream of an interceptor.
(2) If a food scrap interceptor has been installed upstream of the grease interceptor, equipment discharging waste with organic solids may discharge through a grease interceptor.
Text · e-Laws consolidated snapshot
7.4.3.4. — Fixtures Located in Chemical Storage Locations
(1) A floor drain or other fixture located in an oil transformer vault, a high voltage room or any room where flammable, dangerous or toxic chemicals are stored or handled shall not be connected to a drainage system.
Text · e-Laws consolidated snapshot
7.4.3.5. — Macerating Toilet System
(1) A maceration toilet system shall only be installed,
(a) where no connection to a gravity sanitary drainage system is available, and
(b) in accordance with the manufacturer’s instructions.
Text · e-Laws consolidated snapshot
7.4.3.6. — Drains Serving Elevator Pits
(1) If a floor drain is provided in an elevator pit, it shall be installed in accordance with Section 2.7. of the CSA B44, “Safety Code for Elevators”.
Text · e-Laws consolidated snapshot