7.4.10.8. — Hydraulic Loads on Sanitary Horizontal Drain

(1) Except as permitted by Article 7.4.10.7., the hydraulic load that is drained to a horizontal sanitary drainage pipe shall conform to Table 7.4.10.8., based on the size and slope.

(2) Horizontal sanitary drainage pipe shall be designed to carry no more than 65% of its full capacity.

Editor's note

In the notes to Table-7.4.10.8., the footnote reference numbers are presented inline with a separating space; the e-Laws consolidation renders them as superscript abutting the text. The footnote text is identical.

Text · e-Laws consolidated snapshot

Table 7.4.10.8. Maximum Permitted Hydraulic Load Drained to a Horizontal Sanitary Drainage Pipe Forming Part of Sentences 7.4.10.3.(1), 7.4.10.6.(2) and 7.4.10.8.(1)

Column 1

Column 2

Column 3

Column 4

Column 5

Column 6

Column 7

Drain Size, Nominal in.

Maximum Hydraulic Load, fixture units

Slope(1)

1:400

1:200

1:133

1:100

1:50

1:25

3

---

---

---

---

27

36

4

---

---

---

180

240

300

5

---

---

380

390

480

670

6

---

---

600

700

840

1300

8

---

1400

1500

1600

2250

3370

10

---

2500

2700

3000

4500

6500

12

2240

3900

4500

5400

8300

13000

15

4800

7000

9300

10400

16300

22500

Notes to Table 7.4.10.8.:

(1)Slope is the ratio of rise to run, in whatever measurement units are chosen.