7.4.10.5. — Conversion of Fixture Units to Litres and Gal/min

(1) Except as provided in Sentence 7.4.10.3.(2), where the hydraulic load is to be expressed in litres, fixture units shall be converted as follows:

(a) when the number of fixture units is 260 or fewer, the load is 2 360 L, and

(b) when the number of fixture units exceeds 260, the load is 9.1 L for each fixture unit.

(2) Where the hydraulic load is to be expressed in gal/min, fixture units shall be converted in accordance with Table 7.4.10.5.

Text · e-Laws consolidated snapshot

Table 7.4.10.5. Maximum Probable Drainage Rate, gal/min Forming Part of Sentences 7.4.10.3.(1), 7.4.10.5.(2)

Column 1

Column 2

Column 3

Column 4

Fixture Units in Service

Fixture Units

Fixture Units

Fixture Units

Col. 1

Col. 1 × 10

Col. 1 × 100

100

53

174

900

90

51

164

835

80

49

153

750

70

47

140

680

60

44

128

600

50

41

115

520

40

38

102

435

30

33

88

350

20

27

72

262

10

21

53

174