CodeChronicle

OBC 2006 Division B

7.3.3.4.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 7.3.3.4. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 7.3.3.4. — Pro

7.3.3.4. — Unions and Slip Joints

(1) Running thread and packing nut connections and unions with a gasket seal shall not be used downstream of a trap weir in a drainage system or in a venting system.

(2) A slip joint shall not be used,

(a) in a venting system, or

(b) in a drainage system, except to connect a fixture trap to a fixture drain in an accessible location.

Text · e-Laws consolidated snapshot