OBC 2006 › Division B
7.3.3.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.3.3.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.3.3.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 7.3.3. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 7.3.3. — Pro
7.3.3. — Joints and Connections
Content not available for this version.
7.3.3.1. — Drilled and Tapped Joints
(1) Except as provided in Sentences (2) to (4), no water distributing pipe, drainage pipe or fittings shall be drilled, tapped or swaged.
(2) A water distributing pipe may be drilled or tapped to provide for a mechanically extracted T in copper tubing of Type L or K provided that all branch connections shall be notched and dimpled to limit depth of insertion and conform to the inner contour of the main.
(3) A copper water distributing pipe of 1 in. size or larger may be mechanically swaged to permit the joining of other copper pipe of equal size.
(4) A drainage pipe or fitting may be drilled or tapped,
(a) to provide for the connection of a trap seal primer line,
(b) to connect a device designed to dispense germicidal or odour control chemicals or trap seal water to a floor drain downstream of a vacuum breaker or flush valve in a flush tube connected to a sanitary unit,
(c) to provide a hole for a branch connection to a drainage pipe, where the branch connection is made with a saddle hub as permitted by Article 7.2.10.5. and where the hole is drilled to provide a smooth clean hole of the required size and orientation, or
(d) to provide for the connection of pipe or fittings to metal or rigid plastic pipe and fittings where the pipe or fittings are thick enough to be threaded or are bossed for tapping.
(5) No pipe adaption shall be made by the use of a bushing that leaves a square edge or shoulder on the inside of the pipe or fitting.
Text · e-Laws consolidated snapshot
7.3.3.2. — Reserved.
Content not available for this version.
Editor's note
As filed in O. Reg. 350/06, the heading of this article reads 'Reserved.' with a closing period. The consolidated e-Laws text renders it without the period ('Reserved'); the as-filed heading is retained here.
7.3.3.3. — Prohibition of Welding of Pipes and Fittings
(1) Cast iron soil pipe and fittings shall not be welded.
(2) Galvanized steel pipe and fittings shall not be welded.
Text · e-Laws consolidated snapshot
7.3.3.4. — Unions and Slip Joints
(1) Running thread and packing nut connections and unions with a gasket seal shall not be used downstream of a trap weir in a drainage system or in a venting system.
(2) A slip joint shall not be used,
(a) in a venting system, or
(b) in a drainage system, except to connect a fixture trap to a fixture drain in an accessible location.
Text · e-Laws consolidated snapshot
7.3.3.5. — Increaser or Reducer
(1) Every connection between two pipes of different size shall be made with an increaser or a reducer fitting installed so that it will permit the system to be completely drained.
Text · e-Laws consolidated snapshot
7.3.3.6. — Connection of Dissimilar Materials
(1) Adapters, connectors or mechanical joints used to join dissimilar materials shall be designed to accommodate the required transition.
Text · e-Laws consolidated snapshot
7.3.3.7. — Connection of Roof Drain to Leader
(1) Every roof drain shall be securely connected to a leader and provision shall be made for expansion.
Text · e-Laws consolidated snapshot
7.3.3.8. — Connection of Floor Outlet Fixtures
(1) Every pedestal urinal, floor-mounted water closet or S-trap standard shall be connected to a fixture drain by a floor flange, except that a cast iron trap standard may be caulked to a cast iron pipe.
(2) Except as provided in Sentence (3), every floor flange shall be of brass.
(3) Where cast iron or plastic pipe is used, a floor flange of the same material may be used.
(4) Every floor flange shall be securely set on a firm base and bolted to the trap flange of the fixture, and every joint shall be sealed with a natural rubber, synthetic rubber gasket, or with a closet setting compound.
(5) Where a lead water closet stub is used, the length of the stub below the floor flange shall be at least 75 mm.
Text · e-Laws consolidated snapshot
7.3.3.9. — Expansion and Contraction
(1) The design and installation of every piping system shall, where necessary, include means to accommodate expansion and contraction of the piping system caused by temperature change or building shrinkage.
Text · e-Laws consolidated snapshot
7.3.3.10. — Copper Tube
(1) Types M and DWV copper tube shall not be bent.
(2) Bends in copper tubing of soft or bending temper shall be made with tools manufactured and sized for the purpose.
Text · e-Laws consolidated snapshot
7.3.3.11. — Indirect Connections
(1) Where a fixture or device is indirectly connected, the connections shall be made by terminating the fixture drain above the flood level rim of a directly connected fixture to form an air break.
(2) The size of the air break shall be at least 25 mm.