7.2.9. — Jointing Materials

Content not available for this version.

7.2.9.1. — Cement Mortar

(1) Cement mortar shall not be used for jointing.

Text · e-Laws consolidated snapshot

7.2.9.2. — Solder and Fluxes

(1) Solders for solder joint fittings shall conform to ASTM B32, “Solder Metal” in accordance with the recommended use.

(2) Solders and fluxes having a lead content in excess of 0.2 per cent shall not be used in a potable water system.

(3) Fluxes for soldered joints shall conform to ASTM B813, “Liquid and Paste Fluxes for Soldering Applications of Copper and Copper Alloy and Tube”.

(4) Joints in all copper tube installed underground outside a building or underground inside the building shall be made with either flared or corporation fittings, or brazed using a brazing alloy from the American Welding Society AWS-BCuP range.