3.8.2.3.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.8.2.3. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.8.2.3. — Pro

3.8.2.3. — Washrooms Required to be Barrier-Free

(1) Except where other barrier-free washrooms are provided on the same floor level within 45 m and except within suites of residential occupancy, and buildings exempted in Clauses 3.8.1.1.(1)(a), (b) and (c), in buildings where a washroom is required in accordance with Subsection 3.7.4., a barrier-free path of travel shall be provided to a barrier-free washroom designed to accommodate disabled persons in conformance with the appropriate requirements in Articles 3.8.3.8.v1 to 3.8.3.12.v1

(2) Except as permitted in Sentence (3), where washrooms in excess of those required by Subsection 3.7.4. are provided in a storey to which a barrier-free path of travel is required in conformance with Article 3.8.2.1.v1, these washrooms shall be designed to accommodate disabled persons in conformance with the appropriate requirements in Articles 3.8.3.8.v1 to 3.8.3.12.v1

(3) Washrooms need not conform to the requirements in Sentence (2) provided,

(a) they are located within suites of residential occupancy,

(b) other barrier-free washrooms are provided on the same floor level within 45 m, or

(c) they are located in an individual suite that is,

(i) used for a business and personal services occupancy, a mercantile occupancy or an industrial occupancy,

(ii) less than 300 m2 in area, and

(iii) completely separated from, and without access to, the remainder of the building.

Text · e-Laws consolidated snapshot