OBC 2006 › Division B
3.7.4.7.
Version 1 — in force 2 April 2007
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.7.4.7.
- Version
- v1
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.7.4.7.
- Version
- v1
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 3.7.4.7. — Pro
Base · O. Reg. 350/06 · ext v0 →
O. Reg. 137/07, cl. 21 · ext ← current
In force 2007-04-02
OBC 2012 · continues as 3.7.4.7. — Pro
3.7.4.7. — Plumbing Fixtures for Business and Personal Services Occupancies
Comparing versions
Changed text stands out · unchanged is dimmed
v0 base
Earlier · 2006-12-31(1) Except as provided in Sentence (2), the number of water closets required for business and personal services occupancies shall conform to Table 3.7.4.7.
(2) Not more than one water closet to serve both sexes need be provided in a Group D occupancy having an occupant load of not more than 5 persons.
v1 O. Reg. 137/07
Later · viewing · 2007-04-02(1) Except as provided in Sentence (2), the number of water closets required for business and personal services occupancies shall conform to Table 3.7.4.7.
(2) Not more than one water closet to serve both sexes need be provided in a Group D occupancy having an occupant load of not more than 10 persons.
Provenance
OBC 1997 · continues from 3.7.4.7. — Pro
Base · O. Reg. 350/06 · ext v0 → comparing ×
O. Reg. 137/07, cl. 21 · ext ← current
In force 2007-04-02
OBC 2012 · continues as 3.7.4.7. — Pro