CodeChronicle

OBC 2006 Division B

3.7.4.7.

Version 1 — in force 2 April 2007

In force · amended
Verified · covered Verified against the 2007-04-02–2007-06-30 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.7.4.7. — Pro

Base · O. Reg. 350/06 · ext v0 →

O. Reg. 137/07, cl. 21 · ext ← current

In force 2007-04-02

OBC 2012 · continues as 3.7.4.7. — Pro

3.7.4.7. — Plumbing Fixtures for Business and Personal Services Occupancies

(1) Except as provided in Sentence (2), the number of water closets required for business and personal services occupancies shall conform to Table 3.7.4.7.

(2) Not more than one water closet to serve both sexes need be provided in a Group D occupancy having an occupant load of not more than 10 persons.

Text · e-Laws consolidated snapshot

Table 3.7.4.7. Water Closets for Business and Personal Services Occupancies Forming Part of Sentence 3.7.4.7.(1)

Column 1

Column 2

Number of Persons of Each Sex

Minimum Number of Water Closets for Each Sex

up to 9

1

10 to 24

2

25 to 49

3

50 to 74

4

75 to 100

5

over 100

6 plus 1 for each additional increment of 30 persons of each sex in excess of 100