OBC 2006 › Division B
3.7.1.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.7.1.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.7.1.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 3.7.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 3.7.1. — Pro
3.7.1. — Height and Area of Rooms
Content not available for this version.
3.7.1.1. — Room and Space Height
(1) The height of every room and space shall be sufficient so that the ceiling or ceiling fixtures do not obstruct movement or activities below.
(2) The unobstructed height in dwelling units and sleeping rooms in Group C occupancies shall conform to Subsection 9.5.3.
Text · e-Laws consolidated snapshot
3.7.1.2. — Residential Room Dimensions
(1) The areas of rooms in dwelling units, dormitories, boarding houses and rooming houses shall conform to Part 9.
Text · e-Laws consolidated snapshot
3.7.1.3. — Sleeping Areas in Group B and Child Care Facilities
(1) Except as provided in Sentence (2), a sleeping area in a Group B occupancy shall provide not less than 4.7 m2 per person in a room having,
(a) an area not less than 7 m2,
(b) a horizontal dimension not less than 2 000 mm, and
(c) a ceiling height not less than 2 300 mm.
(2) Sleeping rooms for residents in nursing homes shall have, exclusive of space provided for washrooms and for built-in or portable clothes closets, a floor space not less than,
(a) 10.22 m2 in a single-bed unit,
(b) 16.72 m2 in a two-bed unit,
(c) 25.08 m2 in a three-bed unit, and
(d) 29.73 m2 in a four-bed unit.
(3) A child care facility shall provide sleeping accommodation having not less than 0.93 m2 of floor surface area for each child with not less than 2 300 mm ceiling height over the entire room area.
Text · e-Laws consolidated snapshot
3.7.1.4. — Sleeping Areas in Camps
(1) Recreational camps shall have an area in the sleeping quarters of not less than 3.72 m2 per camper or, if double or triple tier bunk units are used, 2.79 m2 per camper.
(2) A camp for housing of workers shall have an area of not less than 3.72 m2 per employee in every room used for sleeping purposes.
Text · e-Laws consolidated snapshot