OBC 2006 › Division B
3.4.2.2.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.4.2.2.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.4.2.2.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
Provenance
OBC 1997 · continues from 3.4.2.2. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 41 · ext v1 →
In force 2010-01-01
Next: O. Reg. 503/09, cl. 41 · ext (not in force until 2010-01-01) v1 →
OBC 2012 · continues as 3.4.2.2. — Pro
3.4.2.2. — Mezzanine Exiting
(1) Except as permitted by Sentences (2) to (4), a mezzanine shall be provided with exits on the same basis as required for floor areas by this Section.
(2) A mezzanine need not conform to Sentence (1) provided Article 3.2.8.1. does not require it to terminate at a vertical fire separation.
(3) In a floor area that is not sprinklered, a mezzanine need not conform to Sentence (1) where Article 3.2.8.1. does require it to terminate at a vertical fire separation provided the total occupant load of the mezzanine is not more than 60 and,
(a) the area of the mezzanine does not exceed the area limits for rooms and suites in Table 3.3.1.5.A., and
(b) the distance limits in Table 3.3.1.5.A. are not exceeded from any point on the mezzanine to,
(i) the egress doorway from the room in which the mezzanine is located if that room has a single egress doorway, or
(ii) an egress facility leading from the mezzanine if the room in which the mezzanine is located has 2 egress doorways provided in conformance with Subsection 3.3.1.
(4) In a floor area that is sprinklered, a mezzanine need not conform to Sentence (1) where Article 3.2.8.1. does require it to terminate at a vertical fire separation provided the total occupant load of the mezzanine is not more than 60 and,
(a) the area of the mezzanine does not exceed the area limits for rooms and suites in Table 3.3.1.5.B., and
(b) the distance of travel is not more than 25 m when measured from any point on the mezzanine to,
(i) the egress doorway from the room in which the mezzanine is located if that room has a single egress doorway, or
(ii) an egress facility leading from the mezzanine if the room in which the mezzanine is located has 2 egress doorways provided in conformance with Subsection 3.3.1.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 3.4.2.2. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 41 · ext v1 →
In force 2010-01-01 compare
Next: O. Reg. 503/09, cl. 41 · ext (not in force until 2010-01-01) v1 →
OBC 2012 · continues as 3.4.2.2. — Pro