CodeChronicle

OBC 2006 Division B

3.3.1.13.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.3.1.13. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.3.1.13. — Pro

3.3.1.13. — Ramps and Stairways

(1) Except as permitted by Sentence (2), Article 3.3.4.7.v1, and Subsection 3.3.2., ramps and stairways that do not serve as exits shall conform to the dimensional, guard, handrail and slip-resistance requirements for exit ramps and stairways of Sentence 3.4.3.2.(7)v1, and Articles 3.4.3.5., and 3.4.6.1. to 3.4.6.8.

(2) Ramps and stairways that do not conform to the requirements of Sentence (1) and are intended only for occasional use for servicing equipment and machinery are permitted,

(a) to serve service rooms and service spaces, and

(b) in industrial occupancies.

Text · e-Laws consolidated snapshot