CodeChronicle

OBC 2006 Division B

3.3.1.12.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.3.1.12. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.3.1.12. — Pro

3.3.1.12. — Doors and Door Hardware

(1) A door that opens into or is located within a public corridor or other facility that provides access to exit from a suite shall,

(a) provide a clear opening of not less than 800 mm if there is only one door leaf,

(b) in a doorway with multiple leaves, have the active leaf providing a clear opening of not less than 800 mm, and

(c) not open onto a step.

(2) A door in an access to exit shall be readily openable in travelling to an exit without requiring keys, special devices or specialized knowledge of the door opening mechanism, except that this requirement does not apply to a door serving a contained use area, or an impeded egress zone, provided the locking devices conform to Sentence (6).

(3) Except as permitted by Sentence (4), door release hardware shall be operable by one hand and the door shall be openable with not more than one releasing operation.

(4) An egress door from an individual dwelling unit or from a suite of residential occupancy is permitted to be provided with additional devices that require a releasing operation additional to the main door release hardware, provided the devices are readily operable from the inside without the use of keys, special devices or specialized knowledge.

(5) Door release hardware shall be installed not more than 1 200 mm above the finished floor.

(6) An egress door in an access to exit serving a contained use area or an impeded egress zone is permitted to be equipped with locking devices that can be released either locally or remotely in conformance with Sentence (7) or Sentence (8).

(7) Local locking devices permitted by Sentence (6) shall be operable by a key from both sides of the door.

(8) Controls for the remote release of door locking devices permitted by Sentence (6) shall be located in an area readily available to security personnel.

(9) Locking devices permitted by Sentence (6) that are electrically operated shall be,

(a) designed to operate on emergency power, and

(b) capable of manual release by security personnel.

(10) A door in an access to exit is permitted to be equipped with an electromagnetic locking device conforming to Sentence 3.4.6.15.(4)v1, except that this permission does not apply to a door,

(a) in an elementary or secondary school,

(b) a door leading from a Group F, Division 1 occupancy, or

(c) except as provided in Sentence (11), requiring a latch release device by Article 3.3.2.6.

(11) A door in an access to exit in a gaming premise is permitted to be equipped with an electromagnetic locking device conforming to Sentences 3.4.6.15.(4)v1 and (7).

(12) Except as required in Article 3.3.3.4., in a Group B, Division 2 or 3 occupancy, every door that opens into or is located within a corridor or other facility that provides access to exit shall comply with Sentences (1) and (2) where the door,

(a) serves a service room,

(b) serves an administrative area,

(c) will not be used by non-ambulatory outpatients,

(d) is located within a patient’s or resident’s sleeping room, or

(e) is in a nursing home or home for the aged that will accommodate only ambulatory residents.