3.2.3.6. — Combustible Projections

(1) Except for a building containing one or 2 dwelling units only, combustible projections on the exterior of a wall that could expose an adjacent building to fire spread and are more than 1 000 mm above ground level, including balconies, platforms, canopies, eave projections and stairs, shall not be permitted within,

(a) 1 200 mm of a property line or the centreline of a public way, or

(b) 2 400 mm of a combustible projection on another building on the same property.

Text · e-Laws consolidated snapshot