3.2.3.12.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 3.2.3.11. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.2.3.12. — Pro

3.2.3.12. — Area Increase for Unprotected Openings

(1) Except as required by Sentence 3.2.3.7.(8), the maximum area of unprotected openings in any exposing building face or fire compartment of a building that is not sprinklered is permitted to be doubled if the openings are glazed with,

(a) glass block conforming to the requirements of Article 3.1.8.14.v1, or

(b) wired glass assemblies conforming to Supplementary Standard SB-2.

Text · e-Laws consolidated snapshot