CodeChronicle

OBC 2006 Division B

3.16.1.5.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

New in this edition — no OBC 1997 predecessor

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.16.1.5. — Pro

3.16.1.5. — Lighting

(1) Walkways and platforms shall be equipped to provide illumination to an average level not less than 50 lx at floor or tread level and at angles and intersections at changes of level where there are stairs or ramps.

(2) Emergency lighting on walkways, platforms, unenclosed egress stairs and exits providing means of egress shall conform to not less than,

(a) the illumination level in Sentences 3.2.7.3.(2)v1 and (3), and

(b) the duration in Sentence 3.2.7.4.(1).

Text · e-Laws consolidated snapshot