3.1.3. — Multiple Occupancy Requirements

Content not available for this version.

3.1.3.1. — Separation of Major Occupancies

(1) Except as permitted by Sentences (2) and (3), major occupancies shall be separated from adjoining major occupancies by fire separations having fire-resistance ratings conforming to Table 3.1.3.1.

(2) In a building not more than 3 storeys in building height, if not more than 2 dwelling units are contained together with a Group E major occupancy, the fire-resistance rating of the fire separation between the 2 major occupancies need not be more than 1 h.

(3) The fire separations required between major occupancies in Sentence (1) are permitted to be penetrated by floor openings protected in conformance with Subsection 3.2.8., except for fire separations for Group F, Division 1 major occupancies and for mezzanines described in Sentence 3.2.8.2.(1)v1v2.

Editor's note

In the notes to Table-3.1.3.1., a separating space follows the footnote reference numbers; the e-Laws consolidation omits it. The footnote text is identical.

Text · e-Laws consolidated snapshot

Table 3.1.3.1. Major Occupancy Fire Separations(1) Forming Part of Sentence 3.1.3.1.(1)

Column 1

Col. 2

Col. 3

Col. 4

Col. 5

Col. 6

Col. 7

Col. 8

Col. 9

Col. 10

Col. 11

Col. 12

Col. 13

Col. 14

Major Occupancy

Minimum Fire-Resistance Rating of Fire Separation, h (1)

Adjoining Major Occupancy

A-1

A-2

A-3

A-4

B-1

B-2

B-3

C

D

E

F-1

F-2

F-3

A-1

---

1

1

1

2

2

2

1

1

2

(2)

2

1

A-2

1

---

1

1

2

2

2

1

1

2

(2)

2

1

A-3

1

1

---

1

2

2

2

1

1

2

(2)

2

1

A-4

1

1

1

---

2

2

2

1

1

2

(2)

2

1

B-1

2

2

2

2

---

2

2

2

2

2

(2)

2

2

B-2

2

2

2

2

2

---

1

2

2

2

(2)

2

2

B-3

2

2

2

2

2

1

---

2

2

2

(2)

2

2

C

1

1

1

1

2

2

2

---

1

2(3)

(2)

2(4)

1

D

1

1

1

1

2

2

2

1

---

---

3

---

---

E

2

2

2

2

2

2

2

2(3)

---

---

3

---

---

F-1

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

3

3

---

2

2

F-2

2

2

2

2

2

2

2

2(4)

---

---

2

---

---

F-3

1

1

1

1

2

2

2

1

---

---

2

---

---

Notes to Table 3.1.3.1.:

(1)Section 3.3. contains requirements for the separation of occupancies and tenancies that are in addition to the requirements for the separation of major occupancies.

(2)See Sentence 3.1.3.2.(1).

(3)See Sentence 3.1.3.1.(2).

(4)See Sentence 3.1.3.2.(2).

3.1.3.2. — Prohibition of Occupancy Combinations

(1) No major occupancy of Group F, Division 1 shall be contained within a building with any occupancy classified as Group A, B or C.

(2) Except as provided in Sentence (4) and Sentence 3.10.2.4.(9), not more than one suite of residential occupancy shall be contained within a building classified as a Group F, Division 2 major occupancy.

(3) A sleeping room or sleeping area shall not open directly into a room or area where food is intended to be stored, prepared, processed, distributed, served, sold or offered for sale.

(4) A Group F, Division 2 major occupancy is permitted in a building containing only live/work units and is for the exclusive use of the occupants of the live/work units.

Text · e-Laws consolidated snapshot