CodeChronicle

OBC 2006 Division B

3.1.15.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.1.15. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.1.15. — Pro

3.1.15. — Roof Covering

Content not available for this version.

3.1.15.1. — Roof Covering Classification

(1) A roof covering classification shall be determined in conformance with CAN/ULC-S107-M, “Fire Tests of Roof Coverings”.

Text · e-Laws consolidated snapshot

3.1.15.2. — Roof Coverings

(1) Except as permitted by Sentence (2), every roof covering shall have a Class A, B or C classification as determined in accordance with Article 3.1.15.1.

(2) A roof covering is not required to have a Class A, B or C classification for

(a) a tent,

(b) an air-supported structure, or

(c) a building of Group A, Division 2 occupancy not more than 2 storeys in building height and not more than 1 000 m2 in building area provided the roof covering is underlaid with noncombustible material.

Text · e-Laws consolidated snapshot