CodeChronicle

OBC 2006 Division B

12.3.3.4.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 9.38.3.2. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

Content moved to SB-12, not yet covered

12.3.3.4. — Metal Framing Elements Acting as Thermal Bridge

(1) Except as provided in Article 12.3.3.5., the thermal resistance of the insulated portion of a building assembly that incorporates metal framing elements, such as steel studs and steel joists, that act as thermal bridges to facilitate heat flow through the assembly, shall be 20 per cent greater than the values shown in Table 12.3.3.3., unless it can be shown that the heat flow is not greater than the heat flow through a wood frame assembly of the same thickness.

Text · e-Laws consolidated snapshot