12.3.2.7. — Minimum Thermal Resistance of Doors

(1) Except for doors on enclosed unheated vestibules and cold cellars, and except for glazed portions of doors, all doors that separate heated space from unheated space shall have a thermal resistance of not less than RSI 0.7 where a storm door is not provided.

(2) All sliding glass doors that separate heated space from unheated space shall have

(a) an overall coefficient of heat transfer of not more than 2.0 W/ m²∙°C, or

(b) an energy rating of not less than 17.

Text · e-Laws consolidated snapshot