CodeChronicle

OBC 2006 Division B

12.3.2.6.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

New in this edition — no OBC 1997 predecessor

Base · O. Reg. 350/06 · ext← current

Original — base regulation

Content moved to SB-12, not yet covered

12.3.2.6. — Thermal Resistance of Windows

(1) Except as permitted in Sentence (2), all windows that separate heated space from unheated space shall have,

(a) an overall coefficient of heat transfer of not more than 2.0 W/ m²∙°C, or

(b) an energy rating of not less than,

(i) 17 for operable windows, and

(ii) 27 for fixed windows.

(2) A basement window that incorporates a loadbearing structural frame shall be double glazed with a low-E coating.

Text · e-Laws consolidated snapshot