CodeChronicle

OBC 2006 Division B

12.3.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

New in this edition — no OBC 1997 predecessor

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 12.3.1. — Pro

12.3.1. — General

Content not available for this version.

12.3.1.1. — Application

(1) Except as provided in Sentence (2), this Section applies to the energy efficiency of buildings within the scope of Part 9 intended for occupancy on a continuing basis during the winter months.

(2) This Section does not apply to,

(a) farm buildings, and

(b) areas of buildings intended primarily for manufacturing or commercial or industrial processing.

Text · e-Laws consolidated snapshot

12.3.1.2. — Equipment Efficiency for Buildings of Residential Occupancy

(1) The minimum annual fuel utilization efficiency of a furnace serving a building of residential occupancy shall conform to Table 12.3.1.2.

Text · e-Laws consolidated snapshot

Table 12.3.1.2. Furnace Minimum Annual Fuel Utilization Efficiency Forming Part of Sentence 12.3.1.2.(1)

Column 1

Column 2

Furnace Fuel Source

Minimum Annual Fuel Utilization Efficiency

Natural gas

90%

Propane

90%

Oil

-

12.3.1.3. — Residential Windows and Sliding Glass Doors

(1) The energy rating and the overall coefficient of heat transfer required for windows and sliding glass doors in a residential occupancy shall be determined in conformance with CAN/CSA-A440.2, “Energy Performance Evaluation of Windows and Sliding Glass Doors”.