OBC 2006 › Division B
11.2.1.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 11.2.1.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 11.2.1.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 11.2.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 11.2.1. — Pro
11.2.1. — Classification
Content not available for this version.
11.2.1.1. — Construction Index and Hazard Index
(1) Where proposed construction will result in the change of major occupancy of all or part of an existing building to another major occupancy, the building shall be classified as to its,
(a) construction on the basis of construction index as provided for in this Part including Table 11.2.1.1.A., and
(b) occupancy on the basis of hazard index as provided for in this Part including Tables 11.2.1.1.B. to 11.2.1.1.N.
(2) Small or medium sized existing buildings as determined in Tables 11.2.1.1.B. to 11.2.1.1.N. facing multiple streets may be assigned a hazard index credit of 1, which may be subtracted from the hazard index of the proposed major occupancy to reduce the additional upgrading required by Table 11.4.3.4.A. provided,
(a) the building does not contain a Group B, Division 1; a Group C, or a Group F, Division 1 occupancy, and
(b) fire fighting access complying with Articles 3.2.5.1., 3.2.5.2., 3.2.5.3., 3.2.5.4. and 3.2.5.5. or Subsection 9.10.20., or an approved alternative measure, is provided from all streets.
(3) The requirements of Articles 3.2.2.20. to 3.2.2.83. do not apply to this Part.
Editor's note
As filed in O. Reg. 350/06, the notes to the Tables of this article (Tables 11.2.1.1.A. through N.) place a space after each footnote marker '(N)' and set the 'Notes to Table' headnotes in regular weight. The e-Laws consolidation removes that spacing and renders the headnotes in bold. These presentation differences were not enacted by any amending regulation, and the as-filed notes are retained here.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 | Column 4 | Column 5 |
Fire-Resistance Rating | Type of Construction | C.I.(2) | ||
Floors over Basement | Other Floors | Roof | ||
3 h | 3 h | 1.5 h | Noncombustible | 8(1) |
2 h | 2 h | 1 h | Noncombustible | 7 |
1 h | 1 h | 45 min | Noncombustible | 6 |
45 min | 45 min | 0 h | Noncombustible | 5 |
45 min | 45 min | 45 min | Heavy Timber | 5 |
45 min | 45 min | 45 min | Combustible | 5 |
45 min | 0 h | 0 h | Noncombustible | 4 |
45 min | 45 min | 0 h | Combustible | 4 |
30 min | 0 h | 0 h | Noncombustible | 3 |
30 min | 30 min | 0 h | Combustible | 3 |
0 h | 30 min | 0 h | Combustible | 2 |
0 h | 0 h | 0 h | Combustible | 1(1) |
Notes to Table 11.2.1.1.A.:
(1)C.I. of 1 is lowest fire protection performance level and C.I. of 8 is highest.
(2)Take highest rating for C.I. from Table 11.2.1.1.A. for existing building.
Column 1 | Column 2 | Column 3 | Column 4 |
Group A | Occupancy H.I.(5) | ||
Division 1 | Small | Medium | Large |
Dinner Theatres | 4 | 5 | 6 |
Live Theatres | 4 | 5 | 6 |
Motion Picture Theatres | 4 | 5 | 6 |
Opera Houses | 4 | 5 | 6 |
Television Studios (With Audience) | 4 | 5 | 6 |
Notes to Table 11.2.1.1.B.:
(1)
|
Building Size (Maximum) (2)(3) |
|
|
- 300 occupant load maximum / 1 storey |
Small |
|
- 600 m2 / 600 occupant load maximum / 1 storey with less than 40% 2 storey (6) |
Medium |
|
- Any area / not exceeding 18 m in building height |
Large |
|
- Over 18 m in building height |
H.I. = 7 |
(2) Sizes are based on building area and building height.
(3) Building size is based on the existing building facing one street.
(4) For existing buildings facing multiple streets see Sentence 11.2.1.1.(2) and Table 11.4.3.4.A.
(5) Take lowest rating for H.I. from Table for major occupancy change.
(6) Building may have less than 40% of its area as 2 storey for purposes as described in Clauses 3.2.2.21.(1)(b) and (c).
Column 1 | Column 2 | Column 3 | Column 4 |
Group A | Occupancy H.I.(5) | ||
Division 2 | Small | Medium | Large |
Art Galleries | 3 | 4 | 6 |
Auditoria | 3 | 4 | 6 |
Billiard Halls, Amusement Arcades | 3 | 4 | 6 |
Bowling Alleys | 3 | 4 | 6 |
Churches | 3 | 4 | 6 |
Clubs, Lodges (Non-Residential) | 3 | 4 | 6 |
Community Halls | 3 | 4 | 6 |
Concert Halls | 3 | 4 | 6 |
Court Rooms | 3 | 4 | 6 |
Dance Halls | 3 | 4 | 6 |
Daycare Centres | 3 | 4 | 6 |
Exhibition Halls (Without Sales) | 3 | 4 | 6 |
Exhibition Halls (With Sales) | See Group E | ||
Gaming premises | 3 | 4 | 6 |
Gymnasia (Multi-Purpose) | 3 | 4 | 6 |
Gymnasia (Athletic) | 3 | 4 | 6 |
Lecture Halls | 3 | 4 | 6 |
Libraries | 3 | 4 | 6 |
Licensed Beverage Establishments | 3 | 4 | 6 |
Licensed Clubs, Lodges | 3 | 4 | 6 |
Museums | 3 | 4 | 6 |
Passenger Stations / Depots | 3 | 4 | 6 |
Public Heritage Buildings | 3 | ||
Recreational Piers | 3 | 4 | 6 |
Restaurants | 3 | 4 | 6 |
Schools, Colleges | 3 | 4 | 6 |
Undertaking Premises | 3 | 4 | 6 |
Notes to Table 11.2.1.1.C.:
(1)
|
Building Size (Maximum) (2)(3) |
|
|
- 400 m2 / 1 storey |
Small |
|
- 250 m2 / 3 storey (Public Heritage Building) |
Small |
|
- 800 m2 / 2 storey |
Medium |
|
- Any area / not exceeding 18 m in building height |
Large |
|
- Over 18 m in building height |
H.I. = 7 |
(2) Sizes are based on building area and building height.
(3) Building size is based on the existing building facing one street.
(4) For existing buildings facing multiple streets see Sentence 11.2.1.1.(2) and Table 11.4.3.4.A.
(5) Take lowest rating for H.I. from Table for major occupancy change.
(6) Building exceeding 3 storeys in building height and which are combustible shall be sprinklered..
Column 1 | Column 2 | Column 3 | Column 4 |
Group A | Occupancy H.I.(5) | ||
Division 3 | Small | Medium | Large |
Arenas (No Occupancy On Activity Surface) | 3 | 4 | 6 |
Armouries (No Occupancy On Activity Surface) | 3 | 4 | 6 |
Enclosed Stadia or Grandstand | 3 | 4 | 6 |
Ice Rinks (No Occupancy On Activity Surface) | 3 | 4 | 6 |
Indoor Swimming Pools | 3 | 4 | 6 |
Notes to Table 11.2.1.1.D.:
(1)
|
Building Size (Maximum) (2)(3) |
|
|
- 1000 m2 / 1 storey |
Small |
|
- 2000 m2 / 2 storey |
Medium |
|
- Any area / not exceeding 18 m in building height |
Large |
|
- Over 18 m in building height |
H.I. = 7 |
(2) Sizes are based on building area and building height.
(3) Building size is based on the existing building facing one street.
(4) For existing buildings facing multiple streets see Sentence 11.2.1.1.(2) and Table 11.4.3.4.A.
(5) Take lowest rating for H.I. from Table for major occupancy change.
Column 1 | Column 2 | Column 3 | Column 4 |
Group A | Occupancy H.I.(5) | ||
Division 4 | Small | Medium | Large |
Amusement Park Structures | 2 | 3 | 5 |
Bleachers | 1 | 3 | 5 |
Grandstands (Open) | 1 | 3 | 5 |
Reviewing Stands | 1 | 3 | 5 |
Stadia (Open) | 1 | 3 | 5 |
Notes to Table 11.2.1.1.E.:
(1)
|
Building Size (Maximum) (2)(3) |
|
|
- 2,500 occupant load max./min. limiting distance of 6 m (combustible) |
Small |
|
- 15,000 occupant load maximum (with roof at least ½ rating if combustible) |
Medium |
|
- Unlimited occupant load |
Large |
(2) Sizes are based on building area and building height.
(3) Building size is based on the existing building facing one street.
(4) For existing buildings facing multiple streets see Sentence 11.2.1.1.(2) and Table 11.4.3.4.A.
(5) Take lowest rating for H.I. from Table for major occupancy change.
Column 1 | Column 2 | Column 3 | Column 4 |
Group B | Occupancy H.I.(3)(5) | ||
Division 1 | Small | Medium | Large |
Detention Facilities (Minimum Security)(4) | 4 | 5 | 6 |
Detention Facilities (All Other Types of Security) | 6 | 6 | 7 |
Police Station with Detention | 3 | ||
Notes to Table 11.2.1.1.F.:
(1)
|
Building Size (Maximum)(2) |
|
|
- Any area / 1 storey |
Small |
|
- 600 m2 / 1 storey (Police Station with Detention) |
Small |
|
- Any area (noncombustible) / 2 storey |
Medium |
|
- Any area (noncombustible); 500 m2 (combustible) / 2 storey |
Large |
|
- Over 18 m in building height (noncombustible) |
H.I. = 7 |
|
- Over 500 m2 (combustible) / over 2 storey |
H.I. = 7 |
(2) Sizes are based on building area and building height.
(3) When the size of a building falls into more than one category, the H.I. for the least restrictive is permitted to be used.
(4) Minimum security - means occupants free to exit building in a fire emergency.
(5) Detention occupancy with any H.I. shall be sprinklered.
Column 1 | Column 2 | Column 3 | Column 4 |
Group B | Occupancy H.I.(5)(7) | ||
Division 2 | Small | Medium | Large |
Hospital, Nursing Home, Geriatric, Sanitorium (6) (Immobile) | 4 | 5 | 7 |
Hospital, Nursing Home, Geriatric, Sanitorium (6) (Non-Ambulatory) | 4 | 5 | 6 |
Hospital, Nursing Home, Geriatric, Sanitorium (6) (Ambulatory) | 3 | 4 | 6 |
Psychiatric Hospitals (Maximum Confinement) | 4 | 5 | 7 |
Psychiatric Hospitals (Minimum Confinement) | 3 | 4 | 6 |
Police Station With Detention | 3 | ||
Notes to Table 11.2.1.1.G.:
(1)
|
Building Size (Maximum)(2)(3) |
|
|
- 250 m2 / 1 storey |
Small |
|
- 600 m2 / 1 storey (Police Station with Detention) |
Small |
|
- 500 m2 / 2 storey; 1000 m2 / 1 storey |
Medium |
|
- Any area (noncombustible); 500 m2 (combustible) / 2 storey |
Medium |
|
- Any area / not exceeding 18 m in building height |
Large |
|
- Over 18 m in building height |
H.I. = 7 |
(2) Sizes are based on building area and building height.
(3) Building size is based on the existing building facing one street.
(4) For existing buildings facing multiple streets see Sentence 11.2.1.1.(2) and Table 11.4.3.4.A.
(5) When the size of a building falls into more than one category, the H.I. for the least restrictive is permitted to be used.
(6) Immobile-means patients attached to life support systems and cannot be moved. Non-Ambulatory-means patients confined to bed and require transportation. Ambulatory-means patients may walk on their own.
(7) Care and treatment occupancy with any H.I. shall be sprinklered.
Column 1 | Column 2 | Column 3 | Column 4 |
Group B | Occupancy H.I.(4)(5) | ||
Division 3 | Small | Medium | Large |
Residential care facilities | |||
(Ambulatory) | 3 | 4 | 6 |
(Non-Ambulatory) | 4 | 5 | 6 |
Children Custodial Homes | 3 | 4 | 6 |
Convalescent Homes | |||
(Ambulatory) | 3 | 4 | 6 |
(Non-Ambulatory) | 4 | 5 | 6 |
Orphanages | 3 | 4 | 6 |
Sanatoria Without Detention Quarter | |||
(Min. Confinement) | 3 | 4 | 6 |
(Max. Confinement) | 4 | 5 | 6 |
Group Homes For Developmentally Handicapped Residents | |||
(Min. Confinement) | 3 | 4 | 6 |
(Max. Confinement) | 4 | 5 | 6 |
Notes to Table 11.2.1.1.H.:
(1)
|
Building Size (Maximum)(2)(3) |
|
|
- 600 m2 / 1 storey |
Small |
|
- 500 m2 / 2 storey; 1000 m2 / 1 storey |
Medium |
|
- Any area / not exceeding 18 m in building height |
Large |
|
- Over 18 m in building height |
H.I. = 7 |
(2) Sizes are based on building area and building height
(3) Building sizes is based on the existing building facing one street
(4) When the size of a building falls into more than one category, the H.I. for the least restrictive is permitted to be used.
(5) Care occupancy with any H.I. shall be sprinklered.
Column 1 | Column 2 | Column 3 | Column 4 |
Group C | Occupancy H.I.(4) | ||
Small | Medium | Large | |
Apartments | 3 | 4 | 6 |
Boarding Houses/Group Homes | 3 | ||
Clubs, Residential | 3 | 4 | 6 |
Colleges, Residential | 3 | 4 | 6 |
Convents | 3 | 4 | 6 |
Dormitories/Hostels | 3 | 4 | 6 |
Hotels | 3 | 5 | 6 |
Houses | 2 | 2 | |
Lodging Houses | 3 | ||
Live/work units | 4 | 5 | 7 |
Monasteries | 3 | 4 | 6 |
Public Heritage Buildings | 3 | ||
Rectories | 2 | ||
Retirement Homes | 3 | 4 | 6 |
Rooming Houses | 3 | ||
Schools, Residential | 3 | 4 | 6 |
Notes to Table 11.2.1.1.I.:
(1)
Building Size (Maximum) (2)(3) | |
- 600 m2 / 3 storey |
Small |
- 250 m2 / 3 storey (Public Heritage Building) |
Small |
- 2000 m2 / not exceeding 6 storeys |
Medium |
- Any area / not exceeding 36 m in building height |
Large |
- Over 36 m in building height |
H.I. = 7 |
- Hotels over 18 m high, measured between grade and the floor level of the top storey |
H.I. = 7 |
(2) Sizes are based on building area and building height.
(3) Building exceeding 3 storeys in building height and which are combustible shall be sprinklered.
(4) Take lowest rating for H.I. from Table for major occupancy change.
Column 1 | Column 2 | Column 3 | Column 4 |
Group D | Occupancy H.I.(5) | ||
Small | Medium | Large | |
Advertising and Sales Offices | 3 | 3 | 5 |
Automatic Bank Deposit | 3 | 4 | 5 |
Barber/Hairdresser Shops | 3 | 4 | 5 |
Beauty Parlours | 3 | 4 | 5 |
Branch Banks | 3 | 4 | 5 |
Car Rental Premises | 3 | 3 | 5 |
Chiropractic Offices | 3 | 4 | 5 |
Communications Offices (Telephone) | 3 | 4 | 5 |
Communications Offices (Telex) | 3 | 4 | 5 |
Communications Offices (Courier) | 3 | 3 | 5 |
Computer Centres | 3 | 4 | 5 |
Construction Offices | 3 | 3 | 5 |
Costume Rental Premises | 3 | 4 | 5 |
Dental Offices (Denture Clinic) | 3 | 4 | 5 |
Dental Offices (General) | 3 | 4 | 5 |
Dental Offices (Surgical/Anaesthesia) | 4 | 5 | 6 |
Dry Cleaning Depots | 3 | 4 | 5 |
Dry Cleaning Premises (Self-Serve) | 4 | 4 | 5 |
Health/Fitness Clubs | 3 | 4 | 5 |
Laundries (Self-Serve) | 4 | 4 | 5 |
Massage Parlours | 3 | 4 | 5 |
Medical Offices (Examination) | 3 | 4 | 5 |
Medical Offices (Surgical/Anaesthesia) | 4 | 5 | 6 |
Offices (Business) | 3 | 3 | 5 |
Offices (Charitable) | 3 | 3 | 5 |
Offices (Legal/Accounting) | 3 | 3 | 5 |
Offices/Studios (Design) | 3 | 4 | 5 |
Pharmacy Offices | 3 | 4 | 5 |
Photographic Studios | 3 | 4 | 5 |
Physiotherapy Offices | 3 | 4 | 5 |
Police Stations (No Detention) | 3 | 4 | 5 |
Printing and Duplicating | 4 | 5 | 6 |
Public Heritage Buildings | 3 | ||
Public Saunas | 3 | 4 | 5 |
Radio Stations (No Audience) | 3 | 4 | 5 |
Small Tool Rental Premises | 3 | 4 | 5 |
Suntan Parlours | 3 | 4 | 5 |
Veterinary Offices | 3 | 4 | 5 |
Notes to Table 11.2.1.1.J.:
(1)
|
Building Size (Maximum) (2)(3) |
|
|
- 800 m2 / 2 storey |
Small |
|
- 250 m2 / 3 storey (Public Heritage Building) |
Small |
|
- 1600 m2 / 3 storey |
Medium |
|
- Any area / not exceeding 18 m in building height |
Large |
|
- Over 18 m, but not exceeding 36 m in building height |
H.I. = 6 |
|
- Over 36 m in building height |
H.I. = 7 |
(2) Sizes are based on building area and building height.
(3) Building size is based on the existing building facing one street.
(4) For existing buildings facing multiple streets see Sentence 11.2.1.1.(2) and Table 11.4.3.4.A.
(5) When the size of a building falls into more than one category, the H.I. for the least restrictive is permitted to be used.
Column 1 | Column 2 | Column 3 | Column 4 |
Group E | Occupancy H.I.(5) | ||
Small | Medium | Large | |
Automotive/Hardware Department Stores | 4 | 5 | 7 |
China Shops | 3 | 4 | 6 |
Department Stores | 4 | 5 | 7 |
Electrical Stores (Fixtures) | 3 | 3 | 5 |
Exhibition Halls (With Sales) | 4 | 5 | 7 |
“Fast Food” Outlets | 3 | 4 | 5 |
Feed and Seed Stores | 4 | 5 | 7 |
Flea Markets | 4 | 5 | 7 |
Flowers Shops | 3 | 4 | 6 |
“Food” and Vegetable Markets | 3 | 4 | 6 |
Garden Shops | 3 | 4 | 6 |
“Gas” Bars | 4 | 5 | 7 |
Gift Shops | 3 | 4 | 6 |
Home Improvement Stores | 4 | 5 | 7 |
Kitchen/Bathroom Cupboards Stores | 3 | 4 | 6 |
Plumbing Stores (Fixtures/Accessories) | 3 | 3 | 5 |
“Pop” Shops | 3 | 4 | 6 |
Public Heritage Buildings | 3 | ||
Rentals (See “Group D”) | |||
Restaurants (Not More Than 30 Persons) | 3 | 4 | 5 |
Shopping Malls | 4 | 5 | 7 |
Stationery/Office Supply Stores | 3 | 4 | 6 |
Stores (Art) | 3 | 4 | 6 |
Stores (Baked Goods) | 3 | 4 | 6 |
Stores (Beer) | 3 | 4 | 6 |
Stores (Book) | 3 | 4 | 6 |
Stores (Camera) | 3 | 4 | 6 |
Stores (Candy) | 3 | 4 | 6 |
Stores (Clothing) | 3 | 4 | 6 |
Stores (Drugs) | 4 | 4 | 6 |
Stores (Electronic) | 3 | 4 | 6 |
Stores (Floor Coverings) | 4 | 5 | 7 |
Stores (Food) | 3 | 3 | 6 |
Stores (Furniture/Appliances) | 3 | 4 | 6 |
Stores (Hardware) | 4 | 5 | 7 |
Stores (Health) | 4 | 4 | 6 |
Stores (Hobby) | 3 | 4 | 6 |
Stores (Jewellery) | 3 | 3 | 5 |
Stores (Paint/Wallpaper) | 4 | 5 | 7 |
Stores (Pet) | 3 | 4 | 6 |
Stores (Records/Tapes) | 3 | 4 | 6 |
Stores (Spirits) | 4 | 5 | 7 |
Stores (Toys) | 4 | 5 | 7 |
Stores (Variety) | 4 | 4 | 6 |
Stores (Video Sales/Rental) | 3 | 4 | 6 |
Supermarkets | 3 | 4 | 6 |
Notes to Table 11.2.1.1.K.:
(1)
|
Building Size (Maximum) (2)(3) |
|
|
- 600 m2 / 2 storey - 250 m2 / 3 storey (Public Heritage Building) - 800 m2 / 3 storey - Any area / up to 18 m in building height - Over 18 m in building height |
Small Small Medium Large H.I. = 7 |
(2) Sizes are based on building area and building height.
(3) Building size is based on the existing building facing one street.
(4) For existing buildings facing multiple streets see Sentence 11.2.1.1.(2) and Table 11.4.3.4.A.
(5) When the size of a building falls into more than one category, the H.I. for the least restrictive is permitted to be used.
(6) All buildings 1500 m2 and over are to be sprinklered.
Column 1 | Column 2 | Column 3 | Column 4 |
Group F | Occupancy H.I.(3) | ||
Division 1 | Small | Medium | Large |
Ammunition Manufacturing and Storage | 3 | 6 | 8 |
Black Powder Manufacturing and Storage | 3 | 6 | 8 |
Bulk Plants for Flammable Liquids | 3 | 6 | 8 |
Bulk Storage Warehouse (Hazardous Substances) | 3 | 6 | 8 |
Cereal and Feed Mills | 3 | 6 | 8 |
Chemical Manufacturing/Processing Plant | 3 | 6 | 8 |
Distilleries | 3 | 6 | 8 |
Dry Cleaning Plants (Flammable) | 3 | 6 | 8 |
Explosives Manufacturing and Storage | 3 | 6 | 8 |
Fertilizer Manufacturing Plants | 3 | 6 | 8 |
Fireworks Manufacturing and Storage | 3 | 6 | 8 |
Flour Mills | 3 | 6 | 8 |
Gas (Flammable) Compressor Stations | 3 | 6 | 8 |
Gas (Flammable) Manufacturing and Storage | 3 | 6 | 8 |
Grain Elevators | 3 | 6 | 8 |
Lacquer Factories | 3 | 6 | 8 |
Loading Area for all Group F, Division 1 | 3 | 6 | 8 |
Mattress Factories (High Fire Load) | 3 | 6 | 8 |
Paint/Varnish/Pyroxylin Factories | 3 | 6 | 8 |
Petrochemical Plants | 3 | 6 | 8 |
Refineries | 3 | 6 | 8 |
Rubber Processing Plants | 3 | 6 | 8 |
Spray Painting Operations | 3 | 6 | 8 |
Waste Paper Processing Plants (Dry) | 3 | 6 | 8 |
Notes to Table 11.2.1.1.L.:
(1)
Building Size (Maximum) (2) | |
- 400 m2 / 2 storey |
Small |
- 600 m2 / 4 storey |
Medium |
- 1 500 m2 / 4 storey |
Large |
(2)Sizes are based on building area and building height.
(3)When the size of a building falls into more than one category, the H.I. for the least restrictive is permitted to be used.
(4)All buildings 1 500 m2 and over are to be sprinklered.
(5)All floor assemblies shall be fire separations.
Column 1 | Column 2 | Column 3 | Column 4 |
Group F | Occupancy H.I.(5) | ||
Division 2 | Small | Medium | Large |
Aircraft Hangars | 3 | 5 | 6 |
Abattoirs | 3 | 4 | 5 |
Bakeries | 3 | 5 | 6 |
Body Shops | 3 | 5 | 6 |
Candy Plants | 3 | 4 | 5 |
COLD STORAGE PLANTS | 3 | 5 | 7 |
Combustible Insulation | |||
Flammable Refrigerant | |||
Combustible Packaging | |||
Combustible Insulation | 3 | 5 | 6 |
Flammable Refrigerant | |||
Noncombustible Packaging | |||
Combustible Insulation | 3 | 4 | 5 |
Non-Flammable Refrigerant | |||
Noncombustible Packaging | |||
Noncombustible Insulation | 2 | 3 | 4 |
Non-Flammable Refrigerant | |||
Noncombustible Packaging | |||
Dry Cleaning Establishments (Non-flammable or Non-explosive) | 3 | 4 | 5 |
Electrical Substations | 3 | 4 | 5 |
Factories (High Fire Load) | 3 | 5 | 6 |
Freight Depots (High Fire Load) | 3 | 5 | 6 |
Helicopter Landings (On Roof) | 3 | 4 | 5 |
Laboratories (High Fire Load) | 3 | 5 | 6 |
Laundries (Not Self-Serve) | 3 | 4 | 5 |
Manufacturer Sales (High Fire Load) | 3 | 5 | 6 |
Mattress Factories | 3 | 4 | 5 |
Meat Packing Plants | 3 | 4 | 5 |
Packaging Manufacturers (Cellulose) | 3 | 4 | 5 |
Packaging Manufacturers (Noncombustible) | 2 | 3 | 4 |
Packaging Manufacturers (Plastics) | 3 | 5 | 6 |
Paper Processing Plants (Wet) | 3 | 5 | 6 |
Plaining Mills | 3 | 5 | 6 |
Printing Plants | 3 | 4 | 5 |
Public Heritage Buildings | 3 | 3 | |
Repair Garages | 3 | 5 | 6 |
Sample Display Rooms (High Fire Load) | 3 | 5 | 6 |
Self-Service Storage Buildings | 3 | 4 | 5 |
Service Stations (No Spray Painting) | 3 | 5 | 6 |
Storage Rooms (High Fire Load) | 3 | 5 | 6 |
Television Studios (No Audience) | 3 | 4 | 5 |
Tire Storage | 3 | 5 | 6 |
Warehouses (High Fire Load) | 3 | 5 | 6 |
Welding Shops | 3 | 5 | 6 |
Wholesale Rooms (High Fire Load) | 3 | 5 | 6 |
Wood Working Factories | 3 | 5 | 6 |
Workshops (High Fire Load) | 3 | 5 | 6 |
Notes to Table 11.2.1.1.M.:
(1)
|
Building Size (Maximum) (2)(3) |
|
|
- 600 m2 / 2 storey |
Small |
|
- 800 m2 /4 storey |
Medium |
|
- 600 m2 / 3 storey (Public Heritage Building) |
Medium |
|
- Any area / 6 storey not exceeding 18 m in building height |
Large |
|
- Over 18 m in building height |
H.I. = 7 |
(2) Sizes are based on building area and building height.
(3) Building size is based on the existing building facing one street.
(4) For existing buildings facing multiple streets see Sentence 11.2.1.1.(2) and Table 11.4.3.4.A.
(5) When the size of a building falls into more than one category, the H.I. for the least restrictive is permitted to be used.
(6) All buildings 1500 m2 and over are to be sprinklered.
Column 1 | Column 2 | Column 3 | Column 4 |
Group F | Occupancy H.I.(5) | ||
Division 3 | Small | Medium | Large |
Creameries | 2 | 2 | 3 |
Factories (Low Fire Load) | 2 | 3 | 4 |
Freight Depots (Low Fire Load) | 2 | 3 | 4 |
Laboratories (Low Fire Load) | 2 | 3 | 4 |
Manufacturers Sales (Low Fire Load) | 2 | 3 | 4 |
Power Plants | 3 | 4 | 5 |
Public Heritage Buildings | 3 | 3 | |
Sample Display Rooms (Low Fire Load) | 2 | 3 | 4 |
Storage Garages | 2 | 3 | 4 |
Storage Rooms (Low Fire Load) | 2 | 3 | 4 |
Warehouses (Low Fire Load) | 2 | 3 | 4 |
Wholesale Rooms (Low Fire Load) | 2 | 3 | 4 |
Workshops (Low Fire Load) | 2 | 3 | 4 |
Notes to Table 11.2.1.1.N.:
(1)
|
Building Size (Maximum) (2)(3) |
|
|
- 800 m2 / 2 storey |
Small |
|
- 1200 m2 / 4 storey |
Medium |
|
- 600 m2 / 3 storey (Public Heritage Building) |
Medium |
|
- Any area / 6 storey not exceeding 18 m in building height |
Large |
|
- Over 18 m, but not exceeding 36 m in building height |
H.I. = 5 |
|
- Over 36 m in building height |
H.I. = 6 |
(2) Sizes are based on building area and building height.
(3) Building size is based on the existing building facing one street.
(4) For existing buildings facing multiple streets see Sentence 11.2.1.1.(2) and Table 11.4.3.4.A.
(5) When the size of a building falls into more than one category, the H.I. for the least restrictive is permitted to be used.
11.2.1.2. — Multiple Occupancies
(1) The classification of an existing building of multiple occupancy under Article 11.2.1.1.v1 shall be applied according to Articles 3.2.2.5. to 3.2.2.8.
Text · e-Laws consolidated snapshot
11.2.1.3. — Prohibition of Occupancy Combinations
(1) Nothing in this Part relieves an applicant from complying with the requirements of Articles 3.1.3.2. or 9.10.9.12.
Editor's note
This map follows the as-filed text of O. Reg. 350/06 for Article 11.2.1.3. of Division B, which refers to 'the requirements of Articles 3.1.3.2. or 9.10.9.12.' using the plural 'Articles'. The e-Laws consolidation editorially renders the reference in the singular as 'Article', with no amending regulation making the change. This map preserves the as-filed wording.
Provenance
OBC 1997 · continues from 11.2.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 11.2.1. — Pro