CodeChronicle

OBC 2006 Division B

10.4.1.1.

Version 1 — in force 1 January 2010

In force · amended
Verified · covered Verified against the 2010-01-01–2010-03-31 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 10.4.1.1. — Pro

Base · O. Reg. 350/06 · ext v0 →

O. Reg. 503/09, cl. 211(2) · ext ← current

In force 2010-01-01

OBC 2012 · continues as 10.4.1.1. — Pro

10.4.1.1. — Substitution

Comparing versions

Changed text stands out · unchanged is dimmed

v0 base

Earlier · 2006-12-31

(1) Except as provided in Sentence (3), a compliance alternative to a requirement contained in Part 3, 4, 5, 6 or 7 that is shown in Tables 11.5.1.1.A., 11.5.1.1.B., 11.5.1.1.C., 11.5.1.1.D/E. or 11.5.1.1.F. may be substituted for the requirement where the chief building official is satisfied that compliance with the requirement is impracticable because,

(a) of structural or construction difficulties, or

(b) it is detrimental to the preservation of a heritage building.

(2) Except as provided in Sentence (3), a compliance alternative to a requirement contained in Part 9 shown in Tables 11.5.1.1.C., 11.5.1.1.D/E. or 11.5.1.1.F. may be substituted for the requirement without satisfying the chief building official that the requirement is impracticable.

(3) Where the building has been in existence for less than five years, compliance alternatives may only be used in respect of requirements of this Division that are referenced in Sentences 10.3.2.2.(3), (5) and Table 10.3.2.2.B.

O. Reg. 350/06, Division B, Part 10.

v1 O. Reg. 503/09

Later · viewing · 2010-01-01

(1) Except as provided in Sentence (3), a compliance alternative to a requirement contained in Part 3, 4, 6 or 8 that is shown in Tables 11.5.1.1.A., 11.5.1.1.B., 11.5.1.1.C., 11.5.1.1.D/E. or 11.5.1.1.F. may be substituted for the requirement where the chief building official is satisfied that compliance with the requirement is impracticable because,

(a) of structural or construction difficulties, or

(b) it is detrimental to the preservation of a heritage building.

(2) Except as provided in Sentence (3), a compliance alternative to a requirement contained in Part 9 or 12 shown in Tables 11.5.1.1.C., 11.5.1.1.D/E. or 11.5.1.1.F. may be substituted for the requirement without satisfying the chief building official that the requirement is impracticable.

(3) Where the building has been in existence for less than five years, compliance alternatives may only be used in respect of requirements of this Division that are referenced in Sentences 10.3.2.2.(3), (5) and Table 10.3.2.2.B.

O. Reg. 350/06, Division B, Part 10; O. Reg. 137/07, ss. 67, 68; O. Reg. 503/09, s. 211.