10.4.1.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 10.4.1.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

O. Reg. 503/09, cl. 211(2) · ext v1 →

In force 2010-01-01

Next: O. Reg. 503/09, cl. 211(2) · ext (not in force until 2010-01-01) v1 →

OBC 2012 · continues as 10.4.1.1. — Pro

10.4.1.1. — Substitution

(1) Except as provided in Sentence (3), a compliance alternative to a requirement contained in Part 3, 4, 5, 6 or 7 that is shown in Tables 11.5.1.1.A.v1, 11.5.1.1.B.v1, 11.5.1.1.C.v1, 11.5.1.1.D/E.v1 or 11.5.1.1.F.v1 may be substituted for the requirement where the chief building official is satisfied that compliance with the requirement is impracticable because,

(a) of structural or construction difficulties, or

(b) it is detrimental to the preservation of a heritage building.

(2) Except as provided in Sentence (3), a compliance alternative to a requirement contained in Part 9 shown in Tables 11.5.1.1.C.v1, 11.5.1.1.D/E.v1 or 11.5.1.1.F.v1 may be substituted for the requirement without satisfying the chief building official that the requirement is impracticable.

(3) Where the building has been in existence for less than five years, compliance alternatives may only be used in respect of requirements of this Division that are referenced in Sentences 10.3.2.2.(3)v1, (5) and Table 10.3.2.2.B.v1