CodeChronicle

OBC 2006 Division A

1.1.3.1.

Version 1 — in force 1 January 2010

In force · amended
Verified · covered Verified against the 2010-01-01–2010-03-31 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 2.1.3.1. — Pro

Base · O. Reg. 350/06 · ext v0 →

O. Reg. 503/09, cl. 4 · ext ← current

In force 2010-01-01

OBC 2012 · continues as 1.1.3.1. — Pro

1.1.3.1. — Building Size Determination of Building Divided by Firewalls

(1) Where a firewall divides a building, each portion of the building that is divided shall be considered as a separate building, except for the purposes of,

(a) a determination of gross area in Section 1.2. of Division C,

(b) a fire alarm and detection system in Sentence 3.2.4.2.(1) of Division B or Article 9.10.18.1. of Division B, and

(c) a plumbing system interconnected through a firewall.

Text · e-Laws consolidated snapshot