(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
(7) Subsection 7 (3) and sections 134, 180, 224 to 230, 235 and 239 come into force on January 1, 2012.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(7)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- C
- Provision
- 1.3.3.2.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
(7) Subsection 7 (3) and sections 134, 180, 224 to 230, 235 and 239 come into force on January 1, 2012.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(7)
Provenance
OBC 1997 · renumbered from 2.4.3.2. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 226 · ext v1 →
In force 2012-01-01
Next: O. Reg. 503/09, cl. 226 · ext (not in force until 2012-01-01) v1 →
OBC 2012 · continues as 1.3.3.2. — Pro
1.3.3.2. — Conditions for Residential Occupancy
(1) A person may occupy or permit to be occupied a building intended for residential occupancy that has not been fully completed at the date of occupation provided that,
(a) the building,
(i) is of three or fewer storeys in building height and has a building area not exceeding 600 m²,
(ii) has not more than 1 dwelling unit above another dwelling unit,
(iii) has not more than 2 dwelling units sharing a common means of egress, and
(iv) has no accommodation for tourists,
(b) the following building components and systems are complete, operational and inspected:
(i) required exits, handrails and guards, fire alarm and detection systems, and fire separations,
(ii) required exhaust fume barriers and self-closing devices on doors between an attached or built-in garage and a dwelling unit, and
(iii) water supply, sewage disposal, lighting and heating systems,
(c) the following building components and systems are complete, operational, inspected and tested:
(i) water systems,
(ii) building drains and building sewers, and
(iii) drainage systems and venting systems, and
(d) where applicable, the building conforms to Article 3.1.1.3. or 9.1.1.7. of Division B.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · renumbered from 2.4.3.2. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 226 · ext v1 →
In force 2012-01-01 compare
Next: O. Reg. 503/09, cl. 226 · ext (not in force until 2012-01-01) v1 →
OBC 2012 · continues as 1.3.3.2. — Pro