CodeChronicle

OBC 2006 Division B

9.9.3.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.9.3. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.9.3. — Pro

9.9.3. — Dimensions of Means of Egress

Content not available for this version.

9.9.3.1. — Application

(1) This Subsection applies to every means of egress except exits that serve not more than one dwelling unit and access to exits within dwelling units.

Text · e-Laws consolidated snapshot

9.9.3.2. — Exit Width

(1) Except for doors and corridors, the width of every exit facility shall be not less than 900 mm.

Text · e-Laws consolidated snapshot

9.9.3.3. — Width of Corridors

(1) The width of every public corridor, corridor used by the public, and exit corridor shall be not less than 1 100 mm.

Text · e-Laws consolidated snapshot

9.9.3.4. — Clear Height

(1) Except for stairways, doorways and storage garages, the minimum clear height in exits and access to exits shall be 2 100 mm.

(2) The clear height in exits and access to exits in a storage garage shall be not less than 2 000 mm.

Text · e-Laws consolidated snapshot