9.9.10.3. — Required Exit Signs

(1) Except as required in Sentence (2), every exit door shall have an exit sign over or adjacent to it when the exit serves,

(a) a 3 storey building,

(b) a building with an occupant load greater than 150, or

(c) a room or floor area that has a fire escape as part of a required means of egress.

(2) Except for suite doors opening directly to the exterior, every exit serving a hotel shall have an exit sign placed over or adjacent to it.