CodeChronicle

OBC 2006 Division B

9.8.4.2.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · split from 9.8.3.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · renumbered to 9.8.4.1. — Pro

9.8.4.2. — Dimensions for Risers

(1) Risers shall conform to Table 9.8.4.2.

Editor's note

In the notes to Table-9.8.4.2., the footnote reference numbers are presented inline with a separating space; the e-Laws consolidation renders them as superscript abutting the text. The footnote text is identical.

Text · e-Laws consolidated snapshot

Table 9.8.4.2. Riser Height, Run and Tread Depth for Rectangular Treads Forming Part of Sentences 9.8.4.2.(1) and 9.8.4.3.(1)

Column 1

Column 2

Column 3

Column 4

Column 5

Column 6

Column 7

Stair Type

All Steps

Rectangular Treads

Rise, mm

Run, mm

Tread Depth, mm

max.

min.

max.

min.

max.

min.

Service and mezzanines in live/work units(1)

no limit

125

355

no limit

355

no limit

Private(2)

200

125

355

210

355

235

Public(3)

200

125

355

230

355

250

Notes to Table 9.8.4.2.:

(1)Service stairs serve areas used only as service rooms or service spaces and stairs that serve mezzanines not exceeding 20 m2 within live/work units.

(2)Private stairs are interior stairs within dwelling units and exterior stairs serving a single dwelling unit.

(3)Public stairs are all stairs not described as service stair or private stairs.