CodeChronicle

OBC 2006 Division B

9.8.10.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.8.10. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.8.10. — Pro

9.8.10. — Cantilevered Precast Concrete Steps

Content not available for this version.

9.8.10.1. — Design

(1) Exterior concrete steps and their anchorage system that are cantilevered from a foundation wall shall be designed and installed to support the loads to which they may be subjected.

Text · e-Laws consolidated snapshot

9.8.10.2. — Anchorage

(1) Cantilevered concrete steps in Article 9.8.10.1. shall be anchored to concrete foundation walls at least 200 mm thick.

Text · e-Laws consolidated snapshot

9.8.10.3. — Prevention of Damage Due to Frost

(1) Suitable precautions shall be taken during backfilling and grading operations to ensure that subsequent freezing of the soil will not cause uplift forces on the underside of cantilevered concrete steps to the extent that the steps or the walls to which they are attached will be damaged.

Text · e-Laws consolidated snapshot