9.7.1.6. — Height of Window Sills above Floors or Ground

(1) Except as provided in Sentence (2), openable windows in buildings of residential occupancy shall be protected by,

(a) a guard in accordance with Subsection 9.8.8., or

(b) a mechanism capable of controlling the free swinging or sliding of the openable part of the window so as to limit any clear unobstructed opening to not more than 100 mm measured either vertically or horizontally where the other dimension is greater than 380 mm.

(2) Windows need not be protected in accordance with Sentence (1) where,

(a) the window serves a dwelling unit that is not located above another suite,

(b) the only opening greater than 100 mm by 380 mm is a horizontal opening at the top of the window,

(c) the top surface of the window sill is located more than 480 mm above the finished floor on one side of the window, or

(d) the window is located in a room or space with the finished floor described in Clause (c) located less than 1 800 mm above the floor or ground on the other side of the window.