CodeChronicle

OBC 2006 Division B

9.6.4.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.6.4.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · merged into 9.7.2.2. — Pro

9.6.4.1. — Height of Door Sills Above Floors or Ground

(1) Doors in buildings of residential occupancy, where the finished floor on one side of the door is more than 600 mm above the floor or other surface or ground level on the other side of the door, shall be protected by,

(a) a guard, in accordance with Subsection 9.8.8., or

(b) a mechanism capable of controlling the free swinging or sliding of the door so as to limit any clear unobstructed opening to not more than 100 mm.

Text · e-Laws consolidated snapshot