(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.4.1.1.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
Provenance
OBC 1997 · continues from 9.4.1.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 137/07, cl. 44 · ext v1 →
In force 2007-04-02
Next: O. Reg. 137/07, cl. 44 · ext (not in force until 2007-04-02) v1 →
OBC 2012 · continues as 9.4.1.1. — Pro
9.4.1.1. — General
(1) Subject to the application limitations defined elsewhere in this Part, structural members and their connections shall,
(a) conform to requirements provided elsewhere in this Part,
(b) be designed according to good engineering practice such as provided in the CWC, “Engineering Guide for Wood Frame Construction”, or
(c) be designed according to Part 4 using the loads and deflection and vibration limits specified in,
(i) this Part,
(ii) Part 4.
(2) Where floor framing is designed in accordance with Clause (1)(b) or (c) and where supporting wall framing and fastenings, or footings are designed according to Clause (1)(a), the specified live load on the floor shall not exceed 2.4 kPa.
(3) Location-specific information for structural design, including snow and wind loads and seismic spectral response accelerations, shall be determined according to Supplementary Standard SB-1.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 9.4.1.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 137/07, cl. 44 · ext v1 →
In force 2007-04-02 compare
Next: O. Reg. 137/07, cl. 44 · ext (not in force until 2007-04-02) v1 →
OBC 2012 · continues as 9.4.1.1. — Pro