CodeChronicle

OBC 2006 Division B

9.37.2.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.37.2. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.37.2. — Pro

9.37.2. — Walls

Content not available for this version.

9.37.2.1. — Logs

(1) Walls may be built of natural or manufactured logs.

Text · e-Laws consolidated snapshot

9.37.2.2. — Attachment of Logs

(1) Walls made of logs in a horizontal position shall have interlocking intersections that will prevent the collection of water in the joints, or the horizontal logs shall butt to a vertical corner post to which the horizontal logs shall be firmly attached.

Text · e-Laws consolidated snapshot

9.37.2.3. — Joining Logs

(1) Each log in a horizontal position shall be scribed as close as possible to its bearer and fastened to the bearer in at least three places throughout its length, by dowels, continuous machined joints, vertical framing members or interlocking intersections or any combination of these, but in no case shall the distance between fastenings exceed 1 800 mm.

Text · e-Laws consolidated snapshot

9.37.2.4. — Vertical Logs

(1) Each log in a wall built of vertical logs shall be scribed to fit as closely as possible to the adjacent logs.

Text · e-Laws consolidated snapshot

9.37.2.5. — Plates

(1) Logs used in a vertical position shall have a plate at the top and a plate at the bottom and the plates shall be at least as wide as the largest end diameter of any of the logs.

Text · e-Laws consolidated snapshot