OBC 2006 › Division B
9.36.2.2.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.36.2.2.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.36.2.2.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 9.36.2.2. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.36.2.2. — Pro
9.36.2.2. — Foundations
(1) Continuous perimeter foundation walls are not required, but when they are provided, they shall comply with the requirements of this Part.
(2) Where unit masonry columns are used, the height of such columns shall not exceed,
(a) in the case of hollow masonry units, 4 times the least dimension of the units,
(b) in the case of solid masonry units or hollow units with voids filled with concrete, 10 times the least dimension of the column, or
(c) where the column is reinforced with at least four 13 mm diameter bars and filled with concrete, 18 times the least dimension of the column.
(3) Columns in excess of the height limitations of Clauses (2)(a) to 2(c) shall be designed in accordance with Part 4.
Editor's note
As filed in O. Reg. 350/06, Sentence (3) cites 'Clauses (2)(a) to 2(c)', with a stray '2' before the closing '(c)'; the consolidated e-Laws text renders the range end in the standard form 'to (c)'. No amending regulation makes this change; the as-filed wording is retained here.