CodeChronicle

OBC 2006 Division B

9.34.2.7.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.34.2.7. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.34.2.7. — Pro

9.34.2.7. — Public and Service Areas

(1) Every public or service area in buildings, including a recreational camp and a camp for housing of workers, shall have lighting outlets with fixtures controlled by a wall switch or panel.

(2) When provided by incandescent lighting, illumination required in Sentence (1) shall conform to Table 9.34.2.7.

(3) When other types of lighting are used, illumination equivalent to that shown in Table 9.34.2.7. shall be provided.

Text · e-Laws consolidated snapshot

Table 9.34.2.7. Lighting for Public Areas Forming Part of Sentences 9.34.2.7.(2) and (3)

Column 1

Column 2

Column 3

Room or Space

Minimum Illumination, lx

Minimum Lighting Power Density, W/M2 of floor area (incandescent lighting)

Storage rooms

50

5

Service rooms and laundry areas

200

20

Garages

50

5

Public water closet rooms

100

10

Service hallways and stairways

50

5

Recreation rooms

100

10

Recreational camps and camps for housing of workers hallways, corridors, stairways and sleeping areas

100

10

Kitchen

500

50

All other rooms

250

25