9.32.3.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.32.3.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.32.3.1. — Pro

9.32.3.1. — General

(1) For the purposes of this Subsection a non-solid fuel-fired appliance shall be classified as,

(a) direct vented whereby the combustion air is supplied directly from the outdoors to the combustion chamber via a sealed passageway, and the products of combustion are exhausted directly outdoors through an independent sealed vent,

(b) mechanically vented induced draft whereby combustion air is supplied from within the building envelope and the products of combustion are positively conveyed to the outdoors by means of a dedicated sealed vent, or

(c) natural draft whereby combustion air is supplied from within the building envelope and the products of combustion are conveyed to the outdoors through a chimney or Type B vent.

(2) For the purposes of this Subsection a dwelling unit shall be categorized as,

(a) Type I when,

(i) all fuel-fired combustion appliances located in the dwelling unit are direct vented or except for fireplaces, are mechanically vented induced draft, and

(ii) the dwelling unit does not contain a solid fuel-fired combustion appliance,

(b) Type II when a solid fuel-fired combustion appliance is installed in a Type I dwelling unit,

(c) Type III when a mechanically vented induced draft non-solid fuel-fired fireplace or a natural draft appliance is present, or

(d) Type IV when electric space heating is present.

Text · e-Laws consolidated snapshot