9.31.6. — Service Water Heating Facilities

Content not available for this version.

9.31.6.1. — Hot Water Temperature

(1) Where a hot water supply is required by Article 9.31.4.3., equipment shall be installed to provide to every dwelling unit an adequate supply of service hot water with a temperature range from 45°C to 60°C.

Text · e-Laws consolidated snapshot

9.31.6.2. — Equipment and Installation

(1) Every service water heater and its installation shall conform to Part 7.

(2) Reserved.

(3) Where the building is in a location where the spectral response acceleration, Sa(0.2), is greater than 0.55, service water heaters shall be secured to the structure to resist overturning and displacement.

Editor's note

As filed in O. Reg. 350/06, Sentence (2) of this article reads 'Reserved.' with a closing period. The consolidated e-Laws text renders it without the period ('Reserved'); the as-filed text is retained here.

9.31.6.3. — Corrosion-Resistant Coating

(1) Where storage tanks for service water heaters are steel, they shall be coated with zinc, vitreous enamel (glass lined), hydraulic cement or other corrosion-resistant material.

Text · e-Laws consolidated snapshot

9.31.6.4. — Fuel-Burning Heaters

(1) Fuel-burning service water heaters shall be connected to a chimney flue conforming to Section 9.21.

Text · e-Laws consolidated snapshot

9.31.6.5. — Heating Coils

(1) Heating coils of service water heaters shall not be installed in a flue or in the combustion chamber of a boiler or furnace heating a building.

Text · e-Laws consolidated snapshot