(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.27.5.4.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 9.27.5.4. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.27.5.4. — Pro
9.27.5.4. — Size and Spacing of Fasteners
(1) Nail or staple size and spacing for the attachment of cladding and trim shall conform to Table 9.27.5.4.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 | Column 4 |
Type of Cladding | Minimum Nail or Staple Length, mm | Minimum Number of Nails or Staples | Maximum Nail or Staple Spacing, mm (o.c.) |
Wood trim | 51 | — | 600 |
Lumber siding or horizontal siding made from sheet metal | 51 | — | 600 |
Metal cladding | 38 | — | 600 (nailed to framing) |
400 (nailed to sheathing only) | |||
Wood shakes | |||
up to 200 mm in width | 51 | 2 | — |
over 200 mm in width | 51 | 3 | — |
Wood shingles | |||
200 mm in width | 32 | 2 | — |
over 200 mm in width | 32 | 3 | — |
Asbestos-cement shingles | 32 | 2 | — |
Panel or sheet type cladding | |||
up to 7 mm thick | 38 | — | 150 (along edges) |
more than 7 mm thick | 51 | — | 300 (along intermediate supports) |