9.27.5.4. — Size and Spacing of Fasteners

(1) Nail or staple size and spacing for the attachment of cladding and trim shall conform to Table 9.27.5.4.

Text · e-Laws consolidated snapshot

Table 9.27.5.4. Attachment of Cladding Forming Part of Sentence 9.27.5.4.(1)

Column 1

Column 2

Column 3

Column 4

Type of Cladding

Minimum Nail or Staple Length, mm

Minimum Number of Nails or Staples

Maximum Nail or Staple Spacing, mm (o.c.)

Wood trim

51

600

Lumber siding or horizontal siding made from sheet metal

51

600

Metal cladding

38

600 (nailed to framing)

400 (nailed to sheathing only)

Wood shakes

up to 200 mm in width

51

2

over 200 mm in width

51

3

Wood shingles

200 mm in width

32

2

over 200 mm in width

32

3

Asbestos-cement shingles

32

2

Panel or sheet type cladding

up to 7 mm thick

38

150 (along edges)

more than 7 mm thick

51

300 (along intermediate supports)